3 CRITICAL ACTIVE Oldest unacknowledged: 3 min ago

Alarm Management

Live · 5 industries · 12 total alerts · Auto-refresh via SignalR

Live
3
Critical Active
Needs immediate action
2
Warning Active
Monitor closely
0
Info Active
Awareness items
3
Acknowledged
Closed today
CRITICAL Oil & Gas Equipment
3 min ago Active
Compressor-C101 · vibration

Compressor-C101 — vibration 6.84 mm/s exceeded threshold 6.0 mm/s — schedule inspection immediately

Current Value
6.84 mm/s
Threshold
≤ 6.0 mm/s
Triggered
14:16:39
View Dashboard
CRITICAL Water Treatment Safety
6 min ago Active
Chlorinator · chlorine

Chlorinator — free chlorine 0.14 mg/L below disinfection minimum 0.20 mg/L — dosing pump check required

Current Value
0.14 mg/L
Threshold
≥ 0.20 mg/L
Triggered
14:13:39
View Dashboard
CRITICAL Food & Beverage Quality
19 min ago Acknowledged
HTST-Pasteurizer · temperature

HTST-Pasteurizer — temperature 71.6 °C below CCP minimum 72.0 °C — divert valve activated

Current Value
71.6 °C
Threshold
≥ 72.0 °C
Triggered
14:00:39
Ack'd By
Priya Sharma
CRITICAL Oil & Gas Safety
1 hr ago Resolved
Separator-V101 · h2s

Separator-V101 — H₂S 11.4 ppm exceeded STEL 10 ppm — area evacuated, ventilation increased, all clear

Current Value
11.4 ppm
Threshold
≤ 10.0 ppm
Triggered
13:05:39
CRITICAL Manufacturing Equipment
1 hr ago Active
Hydraulic-Press · pressure

Hydraulic-Press — E-STOP activated — hydraulic circuit fault, line locked out

Current Value
0 bar
Threshold
> 100 bar
Triggered
12:47:39
View Dashboard
WARNING Energy Utility
11 min ago Active
Grid · power_factor

Grid — power factor 0.88 below target 0.90 — reactive power penalty may apply at next billing cycle

Current Value
0.88
Threshold
≥ 0.90
Triggered
14:08:39
View Dashboard
WARNING Water Treatment Process
14 min ago Active
BoosterP02 · pressure

BoosterP02 — distribution pressure 3.1 bar below operating minimum 3.5 bar — check impeller wear

Current Value
3.1 bar
Threshold
≥ 3.5 bar
Triggered
14:05:39
View Dashboard
WARNING Manufacturing Equipment
37 min ago Acknowledged
Robot-R1 · temperature

Robot-R1 — joint temperature 86.4 °C exceeded limit 85.0 °C — check cooling fan and grease

Current Value
86.4 °C
Threshold
≤ 85.0 °C
Triggered
13:42:39
Ack'd By
Ravi Kumar
WARNING Manufacturing Equipment
51 min ago Resolved
CNC-02 · vibration

CNC-02 — vibration 5.3 mm/s exceeded limit 5.0 mm/s — tooling replaced, monitoring resumed

Current Value
5.3 mm/s
Threshold
≤ 5.0 mm/s
Triggered
13:28:39
WARNING Oil & Gas Equipment
2 hrs ago Resolved
Compressor-C101 · vibration

Compressor-C101 — vibration 4.9 mm/s approaching critical limit 6.0 mm/s — bearing lubrication topped up

Current Value
4.9 mm/s
Threshold
≤ 6.0 mm/s
Triggered
12:11:39
INFO Food & Beverage Process
27 min ago Acknowledged
CIP-Station · temperature

CIP-Station — Line C entered Caustic 80 °C phase — 8-minute cycle in progress

Current Value
78.2 °C
Threshold
≥ 80.0 °C
Triggered
13:52:39
Ack'd By
Arjun Mehta
INFO Energy Utility
1 hr ago Resolved
Solar-Inverter · power

Solar-Inverter — output dropped to 8.2 kW during cloud cover, auto-compensated from grid

Current Value
8.2 kW
Threshold
Normal > 40 kW
Triggered
12:57:39

Alert Timeline

Last 24 hours by severity

Critical Warning Info

By Industry

Oil & Gas
2 crit 3 total
Manufacturing
1 crit 3 total
Water Treatment
1 crit 2 total
Energy
2 total
Food & Beverage
1 crit 2 total

By Category

Alert type distribution

On-Call Roster

Arjun Mehta
Plant Manager
Available
Priya Sharma
Process Engineer
Available
Ravi Kumar
Maintenance Lead
Off-duty
Anjali Singh
Safety Officer
Available

Live Event Stream

SignalR · real-time · last 20 events
--:--:-- Waiting for live events...